| TEST |
TEST
METHOD |
LIMITS |
| RESISTANCE |
<0.005 ohm |
|
| OPERATING TEMPERATURE |
-55o to +155o |
| MAX. CURRENT |
5. amps |
| MAX. WORKING VOLTAGE |
300Vdc |
| MAX. OVERLOAD VOLTAGE |
600Vdc |
| TEMPERATURE COEFFICIENT |
(PPM/oC) 0 ~ - 100 PPM |
| SHORT TIME OVERLOAD |
Apply 2.5 times the voltage rating for 5 sec |
NO VISIBLE DAMAGE |
| LOAD LIFE |
1,000 hrs. at 70oC a direct voltage applied, and cycles
of 1.5 hrs. |
|
| on and 0.5 hrs. off throughout test |
R =
0.5% |
| TEMPERATURE CYCLING |
5 cycles of 30 min. duration at the extremes of temp range, Value
4 hrs. |
|
| Maximum and minimum, measurement of ohmic |
R = 0.5% |
| after completion of test |
|
| DIELECTRIC STRENGTH |
Using a 95o"V" shaped conductive block apply 100V minimum, |
R =
0.5% |
| Increasing 100V/sec. For 5 sec. |
R =
0.5% |
| HUMIDITY |
350 hrs. at 40oC, 90 ~ 95% Rh |
95% OF TESTED |
| SOLDERABILITY |
Dipped in Sn / Pb (60/40) at 235o, 5 sce.
1.5mm from the body |
SURFACE
COVERED |
| VIBRATION |
By Mil STD.202, 201A |
|
| TERMINAL ROBUSTNESS |
Traction, applied 2.5kg. for 10 sec. Bends, 2 bends 90oC
applying Load to
terminals of 0.5kg. Twist. 2 successive turns 180o, 6mm
From body |
|
| RESISTANCE TO SOLVENTS |
Trichlorethylene , TMC as the most aggressives for 60 sec. |
NO VISIBLE DAMAGE |
| At Boiling point. |
NO VISIBLE DAMAGE |